Case Study: Choosing a 24 V Solenoid for Medical Bed Adjustment, Sample Passed Customer Testing

2026-11-03
Case Details

Selecting a Solenoid for Medical Bed Adjustment

A medical equipment manufacturer needed an electromagnetic actuator for a bed adjustment function. They had already discovered that the small solenoids they were evaluating did not behave the same way on the bed as they did on a bench. We supplied a DC24V electromagnet specified against the real working conditions, they tested the sample on their own rig, and it passed — with clear satisfaction from their engineering team.

This case is written as a selection guide rather than a product description, because the same questions come up in every hospital bed project we handle.

Three Bed Functions, Three Different Requirements

Not every actuator on a medical bed is doing the same job. Getting the selection right starts with being honest about which function the solenoid serves:

FunctionWhat the solenoid must doDominated by
Position locking / releaseHold a set position against load, release on commandHolding force at working gap, release reliability
Backrest or legrest adjustment assistActuate repeatedly during adjustment, often held by the operatorForce at stroke, tolerance to extended energisation
Emergency or quick releaseFail to a safe state, work after long idle periodsReliability after inactivity, spring return behaviour

In this project the requirement sat in the middle column: a part that works at a defined stroke, tolerates being energised longer than the nominal duty cycle suggests, and keeps its force after hundreds of thousands of operations.

The Specification That Was Supplied

ItemSpecification
ApplicationMedical bed electromagnet (medical device / DC micro solenoid)
Rated voltageDC 24 V (working range DC 24 V ±10%)
Rated power / coil resistance18.48 W at DC24V, coil 31 Ω ±10%
Operating cycleON : OFF = 0.05 s : 0.15 s; continuous energisation permitted up to 300 s
Force≥ 300 g at 5.8 mm stroke
Operating temperature-20 °C to +45 °C
Insulation resistanceDC 500 V, ≥ 50 MΩ (coil to bobbin)
Dielectric strength700 V, 50/60 Hz, 1 s, leakage ≤ 1 mA (coil to case)
Service lifeOver 500,000 cycles under normal use

Four Selection Rules We Applied

  1. Quote force at the working stroke, not at contact. A solenoid rated at 300 g on contact can deliver a small fraction of that at a 5.8 mm gap. Every specification we issue for a bed application states the force at the stroke the mechanism actually uses.
  2. Design for the worst-case energisation, not the nominal duty cycle. The 0.05 s / 0.15 s duty is the normal pattern; the specification also permits continuous energisation up to 300 s because that is what happens when a nurse holds an adjustment. The coil has to survive the real-world case, not the datasheet case.
  3. Treat electrical safety as a first-class requirement. Insulation resistance at DC500V and dielectric strength with leakage within 1 mA are specified and tested, because on a patient bed these checks — not force — are what device approval hinges on.
  4. Size the life expectancy for the service life. 500,000 cycles for a component in a bed that actuates a few times a day means the solenoid should not be the reason a field service visit happens.

What the Customer Tested

  • Force at stroke, repeated across samples to check consistency rather than a single favourable reading
  • Extended energisation, observing heat build-up inside the housing against the 300 s allowance
  • Insulation and dielectric performance, the data their device approval file needs
  • Cyclic operation, confirming force does not decay and release stays clean
  • Workmanship — no damage, cracking, rust or surface staining

The sample passed the test and the customer confirmed their satisfaction with the part.

If You Are Selecting an Actuator for a Bed or Chair

Send us four things and the selection becomes straightforward: which function the solenoid serves, the required force at the actual stroke, the longest time it may stay energised, and the safety standard the device must meet. We will propose a specification, state clearly what we will commit to in writing, and supply samples for your own rig rather than ours.